Frei lesbar · kostenloses Konto zum MitmachenNachfolger von Anticars (2000)
AnmeldenKonto erstellen
UKDVSA · Vereinigtes KönigreichR/2006/00622. März 2006

Water ingress into abs wiring may cause a short circuit and a fire

Im Original (Englisch) angezeigt · Übersetzung ausstehend

It has been identified that the above vehicles could be affected by moisture ingress at the ABS connector. The moisture can enter through the ground wiring connection which can lead to the ABS not functioning correctly overheating within the connector and in extreme cases a fire.

Abhilfe: Recalled vehicles will have the ABS harness plug checked for moisture ingress and where necessary the wiring harness and control unit will be replaced. In all other cases the ground cable will be secured against ingress of moisture by soldering the cable sockets and applying shrink tubes.

Betrifft: Opel Combo D · Opel Tigra TwinTop B · Vauxhall Nova Corsa E

Offizielle Meldung ↗

Quellen: NHTSA (USA, gemeinfrei), Transport Canada (Open Government Licence – Canada), DVSA (Vereinigtes Königreich, Open Government Licence v3.0), RappelConso und EU-Safety-Gate (Frankreich, Licence Ouverte 2.0).