Electrical circuit that controls current to brake pump motor relay, heater and air conditioning blower motor, turn signals, and a electronic message center may overheat due to inability of ignition circuit wiring connections to dissipate heat generated by electrical loads.
Risiko: Brake pump motor will not operate, substantially reducingbraking capability; brake warning light will come on.
Abhilfe: Replace ignition switch and modify switch wiring.