Electrical system
On certain sport utility vehicles equipped with front bench seats only, if fluid is spilled from the floor mounted cup holder, an unused console power outlet connector located under the seat may become contaminated.
🔔 Create a free account to get email alerts about Dodge Durango I
On certain sport utility vehicles equipped with front bench seats only, if fluid is spilled from the floor mounted cup holder, an unused console power outlet connector located under the seat may become contaminated.
The fasteners which secure the alternator cable to the power distribution center (pdc) may have insufficient clamp load. Insufficient clamping may result in a loose connection and arcing at the connection, which could potentially cause a fire in the engine compartment. Correction: The alternator and battery cable attaching nuts will be torqued at the pdc to the proper specifications.
Vehicle description: Light duty pickup trucks. The fastener which secures the generator cable to the power distribution center (pdc) has an insufficient clamp load, resulting in a loose connection and electrical arcing at the connection.
Sources: NHTSA (United States, public domain), Transport Canada (Open Government Licence – Canada), DVSA (United Kingdom, Open Government Licence v3.0), RappelConso and EU Safety Gate (France, Licence Ouverte 2.0), Japan's MLIT (Public Data License 1.0) and South Korea's MOLIT (car.go.kr).