NATransport Canada1995169Sep 28, 1995

Electrical

A wire inside the electric motor driven gearbox actuator may come into contact with the inner face of the assembly case, causing fretting of the wire and also causing the fuse protecting the circuit to blow if this occurs it would not be possible to engage the desired gear range and may not be possible to restart the vehicle after the engine has been switched off. If "park" is not engaged and the driver does not apply the parking brake, a roll away could occur. Correction: Affected wire will be repositioned.

Concerns: Bentley Azure I (Model years 1994–1996) · Bentley Brooklands I (Model years 1992–1996) · Bentley Continental R (Model years 1992–1996) · Bentley Eight (Model years 1992–1993) · Bentley Mulsanne (Model years 1992–1993) · Bentley Turbo R (Model years 1992–1996) · Rolls-Royce Corniche IV (Model years 1992–1996) · Rolls-Royce Silver Spirit Mark III (Model years 1992–1996) · Rolls-Royce Silver Spirit Mark IV (Model years 1994–1996)