NANHTSA · United States99V333001Nov 23, 1999

Electrical system:12v/24v/48v battery:Cables

Vehicle description: Passenger vehicles equipped with v6 engines and federal emission equipment. The battery cable harness can become heat damaged by the front exhaust manifold which could cause grounded circuits.

Risk: This circuit failure could cause any of the following to occur: (1) the engine will not start because the main fuse will blow if the power lead is grounded; (2) the low oil pressure warning lamp will illuminate if the signal wire is grounded; (3) the airconditioning system will become inoperative if the lead to the magnetic clutch is grounded; and (4) the turn signal/hazard lamps will become inoperative if the voltage monitor lead is grounded.

Remedy: Dealers will remove and discard a metal manifold bracket (from galant models only - eclipse has no such bracket). Dealers will also inspect the harness. If the harness wires show no damage, the dealer will install a heat insulator along with heat resistant harness clips. If the harness wires do show damage, the dealers will install a new harness with preinstalled integral heat protection.

Concerns: Mitsubishi Eclipse III (Model years 2000) · Mitsubishi Galant VIII (Model years 1999–2000)