NANHTSA · United States91V004000Oct 2, 1991

Visibility:Defroster/defogger/hvac system:Fan/motor

Water leaking under windshield cowl in area above heater blower motor resistor block results in corrosion of the resistor terminals.

Risk: Corrosion of the resistor terminals increases electricalresistance, leading to overheating and possble ignition of the wiring connectorsand insulation, causing a fire in the cowl area.

Remedy: The blower motor resistor block will be replaced, and a mastic patch applied to seal the cowl against water entry. Damaged wire connectors will be replaced.

Concerns: Chrysler Fifth Avenue Series Y (Model years 1991) · Chrysler New Yorker Series C (Model years 1990–1991) · Dodge Dynasty (Model years 1990–1991)