Free to read · free account to contributeSuccessor to Anticars (2000)
Sign inCreate account
NANHTSA · manufacturer bulletin10228391

Service bulletins

The fuel metering valve of the high-pressure fuel pump is controlled by a specific on/off ratio. If there is a low system voltage, the on/off ratio may not be enough to keep the fuel metering valve constant in all areas. In such a situation, the fuel metering valve is deactivated and the high-pressure fuel pump switches to full supply mode. Because the increased rail pressure does not match the respective driving situation, the DTC appears.

Concerns: Audi S6 IV (C6) (Model years 2013)

Official notice ↗