Lettura libera · account gratuito per contribuireErede di Anticars (2000)
AccediCrea un account
NANHTSA · Stati Uniti97V0590008 apr 1997

Electrical system:Wiring:Front underhood

Mostrato in inglese originale · traduzione in attesa

The protective cover for the underhood fuse center was omitted. Without this cover, the positive terminal bolt on the fuse block is exposed and can contact the insulated negative battery cable. If the insulation on the negative cable becomes sufficiently worn, an electrical short circuit can occur between the positive terminal and negative cable resulting in extremely high current flow.

Rischio: This high current flow can cause arcing and result in an underhood fire.

Rimedio: Dealers will inspect these vehicles for the presence of the protective cover and, if necessary, install a protective cover to the underhood fuse center.

Riguarda: Buick Skylark VII (Anni modello 1997) · Oldsmobile Achieva (Anni modello 1997) · Pontiac Grand Am IV (Anni modello 1997)

Avviso ufficiale ↗

Fonti: NHTSA (Stati Uniti, pubblico dominio), Transport Canada (Open Government Licence – Canada), DVSA (Regno Unito, Open Government Licence v3.0), RappelConso e Safety Gate UE (Francia, Licence Ouverte 2.0), MLIT (Giappone, Public Data License 1.0) e MOLIT (Corea del Sud, car.go.kr).