The fuel metering valve of the high-pressure fuel pump is controlled by a specific on/off ratio. If there is a low system voltage, the on/off ratio may not be enough to keep the fuel metering valve constant in all areas. In such a situation, the fuel metering valve is deactivated and the high-pressure fuel pump switches to full supply mode. Because the increased rail pressure does not match the respective driving situation, the DTC appears.
NANHTSA · bollettino del costruttore10225070
Bollettini tecnici
Mostrato in inglese originale · traduzione in attesa
Riguarda: Audi S6 IV (C6) (Anni modello 2013)
Fonti: NHTSA (Stati Uniti, pubblico dominio), Transport Canada (Open Government Licence – Canada), DVSA (Regno Unito, Open Government Licence v3.0), RappelConso e Safety Gate UE (Francia, Licence Ouverte 2.0), MLIT (Giappone, Public Data License 1.0) e MOLIT (Corea del Sud, car.go.kr).