Lettura libera · account gratuito per contribuireErede di Anticars (2000)
AccediCrea un account
NANHTSA · bollettino del costruttore10225070

Bollettini tecnici

Mostrato in inglese originale · traduzione in attesa

The fuel metering valve of the high-pressure fuel pump is controlled by a specific on/off ratio. If there is a low system voltage, the on/off ratio may not be enough to keep the fuel metering valve constant in all areas. In such a situation, the fuel metering valve is deactivated and the high-pressure fuel pump switches to full supply mode. Because the increased rail pressure does not match the respective driving situation, the DTC appears.

Riguarda: Audi S6 IV (C6) (Anni modello 2013)

Avviso ufficiale ↗