Lettura libera · account gratuito per contribuireErede di Anticars (2000)

SaabSaab 9-5

1997–2011 · 2 generazioni · 15 difetti documentati · 3 mercati
Generazioni
Anno modello
9-5 I · 1997–2009
RichiamoCriticoElettronicaNA

Electrical system:Ignition:Module

Certain passenger vehicles equipped with b308 6-cylinder gasoline engines may experience overheating and burnout of the isolated gated bipolar transistor (igbt) within the ignition discharge module (idm) due to increased susceptibility to electrical loads.

NHTSA · Stati Uniti26 ott 200606V410000Anni modello 2002–2003Mostrato in inglese originale · traduzione in attesaVedi dettagli →
9-5 I · 1997–2009
RichiamoCriticoElettronicaNA

Electrical

Certain 2000-2002 Saab 9-3 and 9-5 model vehicles equipped with 4-cylinder gasoline engines, and 2001-2003 9-5 models equipped with 6-cylinder gasoline engines may experience overheating and burnout of the Isolated Gated Bipolar Transistor (IGBT) within the Ignition Discharge Module (IDM) due to increased susceptibility to electrical loads. Overheating of the IGBT occurs most often at engine start-up but may also occur while the engine is running. When the IDM fails on a 4-cylinder while it is running, the engine may stall without warning, with no ability to be restarted. When the IDM fails on a 6-cylinder engine while it is running, the driver will initially experience reduced power and rough operation because the engine will only be running on three cylinders. The check engine light will flash. If the driver continues, unburnt fuel in the exhaust can cause thermal damage to the catalytic converter. The engine may stall and not restart. Correction: Dealers will inspect and, if required, replace the IDM.

Transport Canada20 set 20052005271Anni modello 2000–2003Mostrato in inglese originale · traduzione in attesaVedi dettagli →
9-5 I · 1997–2009
RichiamoCriticoElettronicaNA

Electrical system:Ignition:Module

Certain passenger vehicles equipped with b205/b235 4-cylinder gasoline engines and b308 6-cylinder gasoline engines may experience overheating and burnout of the isolated gated bipolar transistor (igbt) within the ignition discharge module (idm) due to increased susceptibility to electrical loads.

NHTSA · Stati Uniti14 set 200505V399000Anni modello 2000–2002Mostrato in inglese originale · traduzione in attesaVedi dettagli →
9-5 I · 1997–2009
RichiamoModeratoElettronicaJP

その他(電気装置)

点火装置において、高電圧発生モジュールのトランジスタの耐久性が不足しているため、電気負荷の繰り返しによりトランジスタが破損し、原動機が停止するおそれがある。

MLIT · Giappone2 lug 20081215030Anni modello 2002–2003Mostrato in giapponese originale · traduzione in attesaVedi dettagli →
9-5 I · 1997–2009
RichiamoModeratoElettronicaJP

その他(電気装置)

原動機室内のスタータモータの電気配線コネクタに防水シールが取り付けられていないも のがあるため、そのままの状態で使用を続けると、当該コネクタ部に水分が混入し、最悪 の場合、コネクタピンが腐食して導通不良となり、原動機が始動できなくなるおそれがあ る。

MLIT · Giappone4 lug 20001208160Anni modello 1999Mostrato in giapponese originale · traduzione in attesaVedi dettagli →

Fonti: NHTSA (Stati Uniti, pubblico dominio), Transport Canada (Open Government Licence – Canada), DVSA (Regno Unito, Open Government Licence v3.0), RappelConso e Safety Gate UE (Francia, Licence Ouverte 2.0), MLIT (Giappone, Public Data License 1.0) e MOLIT (Corea del Sud, car.go.kr).