Potential leakage of battery acid around the battery negative terminal could cause the battery monitoring sensor to fail. Over time growth of copper sulphate may accumulate. This, in turn, could provide a conductive layer underneath the Battery Monitoring Sensor, creating a low resistance to ground. The increased current flow, due to low resistance, could cause the surrounding material to heat up to a point where it ignites, resulting in a fire.
Safety Gate · EU2019년 8월 5일A12/1222/19연식 2014–2019원문(영어)으로 표시 중 · 번역 대기자세히 보기 →
Un problème peut survenir avec le logiciel actuel de l’unité de commande télématique (tcu), ce qui pourrait affecter la fonctionnalité du système ecall. par conséquent, le service d’urgence peut ne pas être contacté en cas de besoin.
Safety Gate · EU · RappelConso · 프랑스2021년 6월 25일info/00130/21연식 2019–2021원문(프랑스어)으로 표시 중 · 번역 대기자세히 보기 →
Vehicles fitted with Adaptive LED Headlamps could experience a condition where the loss of a control signal in combination with a software error may cause the headlamps to switch off. There is a risk of collision if defect happens at night.
DVSA · 영국2016년 6월 20일R/2016/113연식 2014–2016원문(영어)으로 표시 중 · 번역 대기자세히 보기 →
null Vehicles fitted with Adaptive LED Headlamps could experience a condition where the loss of a control signal in combination with a software error may cause the headlamps to switch off. This could lead to an accident.
Safety Gate · EU2016년 6월 15일A12/0768/16연식 2014–2016원문(영어)으로 표시 중 · 번역 대기자세히 보기 →
출처: NHTSA(미국, 퍼블릭 도메인), 캐나다 교통부(Open Government Licence – Canada), DVSA(영국, Open Government Licence v3.0), RappelConso 및 EU Safety Gate(프랑스, Licence Ouverte 2.0), 일본 국토교통성(공공데이터 이용약관 1.0), 한국 국토교통부(자동차리콜센터 car.go.kr).