무료 열람 · 무료 계정으로 기여Anticars(2000)의 후속
로그인계정 만들기
NANHTSA · 미국99V3330011999년 11월 23일

Electrical system:12v/24v/48v battery:Cables

원문(영어)으로 표시 중 · 번역 대기

Vehicle description: Passenger vehicles equipped with v6 engines and federal emission equipment. The battery cable harness can become heat damaged by the front exhaust manifold which could cause grounded circuits.

위험: This circuit failure could cause any of the following to occur: (1) the engine will not start because the main fuse will blow if the power lead is grounded; (2) the low oil pressure warning lamp will illuminate if the signal wire is grounded; (3) the airconditioning system will become inoperative if the lead to the magnetic clutch is grounded; and (4) the turn signal/hazard lamps will become inoperative if the voltage monitor lead is grounded.

조치: Dealers will remove and discard a metal manifold bracket (from galant models only - eclipse has no such bracket). Dealers will also inspect the harness. If the harness wires show no damage, the dealer will install a heat insulator along with heat resistant harness clips. If the harness wires do show damage, the dealers will install a new harness with preinstalled integral heat protection.

해당: Mitsubishi Eclipse III (연식 2000) · Mitsubishi Galant VIII (연식 1999–2000)

공식 공지 ↗

출처: NHTSA(미국, 퍼블릭 도메인), 캐나다 교통부(Open Government Licence – Canada), DVSA(영국, Open Government Licence v3.0), RappelConso 및 EU Safety Gate(프랑스, Licence Ouverte 2.0), 일본 국토교통성(공공데이터 이용약관 1.0), 한국 국토교통부(자동차리콜센터 car.go.kr).