Air Conditioning System Leak Testing. The customer complains of poor or no air conditioning cooling. After further diagnosis, the system is found to be low or empty of a refrigerant charge, but when using an electronic leak detector, no leak can be found. CAUSE: In most cases, an electronic leak detector is not sufficient for identifying small leaks in the system. Electronic leak detectors can give false alarms and can lead to an improper diagnosis of small leaks. A leak cannot be located exactly if accessibility is impaired (in the case of the expansion valve, evaporator or condenser).
NANHTSA · 제조사 공지10162461
기술 서비스 공지
원문(영어)으로 표시 중 · 번역 대기
해당: Mini Hatch II (연식 2009)
출처: NHTSA(미국, 퍼블릭 도메인), 캐나다 교통부(Open Government Licence – Canada), DVSA(영국, Open Government Licence v3.0), RappelConso 및 EU Safety Gate(프랑스, Licence Ouverte 2.0).