VIN: LJUEAEG24SK501115 Occurrence Date: August 26, 2025 Mileage: 9,689 km Location: Lotus Austin On August 26, 2025, a vehicle at Lotus Austin exhibited recurring DSA faults. These faults were initially recovered and erased but reappeared. Following TIS diagnostic procedures for the MVCM (DCDC), technicians confirmed proper voltages, ground, and CAN inbound signals, but found no outbound signal from the module. A cross-change of the MVCM was performed, but the DTC persisted, indicating the MVCM was not the root cause. The 48V SuperCapacitor connector was inspected and found to be secure with correct torque. Diagnostic Trouble Code B167D87 indicated a missing LIN signal from the 48V SuperCapacitor to the VCU. The issue is still under investigation, with possible causes including a functional issue with the 48V SuperCapacitor (low voltage) or a fault in the MVCM cables or connectors. Note: Due to the timing of the fault report, communications were sent in September despite the occurrence date being in August.
NANHTSA · boletim do fabricante11024175
Boletins técnicos
Exibido no inglês original · tradução pendente
Abrange: Lotus Eletre (Anos-modelo 2025)
Fontes: NHTSA (Estados Unidos, domínio público), Transport Canada (Open Government Licence – Canada), DVSA (Reino Unido, Open Government Licence v3.0), RappelConso e Safety Gate da UE (França, Licence Ouverte 2.0).