Leitura livre · conta gratuita para contribuirSucessor do Anticars (2000)
EntrarCriar conta
NANHTSA · boletim do fabricante10250374

Boletins técnicos

Exibido no inglês original · tradução pendente

An interference noise (groaning noise) can be heard from within the heating and air-conditioning unit in thecenter of the instrument panel. The groaning noise always occurs when either a ventilation flap, air stratification flap or the recirculated airflap moves to a different position. Due to the complex design of the heating and air-conditioning unit, the kinematics causing it (top or bottom,left or right) may not be able to be precisely located. Depending on the vehicle model, the number of servomotors (and the associated kinematics unit) varies.Various models use either 2 or 3 servomotors.

Abrange: BMW 2 Series II (Anos-modelo 2023) · BMW 3 Series (G20) (Anos-modelo 2023) · BMW 4 Series (Anos-modelo 2020) · BMW 4 Series (G22) (Anos-modelo 2023) · BMW M4 II (Anos-modelo 2023)

Aviso oficial ↗

Fontes: NHTSA (Estados Unidos, domínio público), Transport Canada (Open Government Licence – Canada), DVSA (Reino Unido, Open Government Licence v3.0), RappelConso e Safety Gate da UE (França, Licence Ouverte 2.0), MLIT (Japão, Licença de Dados Públicos 1.0) e MOLIT (Coreia do Sul, car.go.kr).