قراءة مجانية · حساب مجاني للمساهمةخليفة Anticars (2000)

BMW إم 5

1984– · 7 الأجيال · 5 أعطال موثّقة · 3 أسواق
الأجيال

النشرات الفنية (TSB) تعليمات إصلاح يرسلها المصنعون إلى وكلائهم بشأن مشكلات معروفة. ليست استدعاءات سلامة، لكنها كثيرًا ما تؤكد وجود عطل.

سنة الطراز
السوقالكلNA
إم 5 (G90/G99) · 2024–
نشرةمتوسطالكهرباءNA

نشرة

Due to an implementation error in various OBD diagnostics in the vehicle's control units, in very rare cases itmay happen that stored fault memory codes (DTCs) and the MIL (warning light) are not automaticallydeleted even though the underlying malfunction has already been rectified. This does not comply with the statutory OBD specifications.

NHTSA · نشرة المصنع11034449سنوات الطراز 2025معروض باللغة الأصلية (الإنجليزية) · الترجمة قيد الانتظارعرض التفاصيل →
إم 5 (G90/G99) · 2024–
نشرةمتوسطالكهرباءNA

نشرة

Several complaints are possible: Vehicle does not start Gear cannot be engaged Various Check Control Messages Malfunction indicator lamp (MIL) on Several Check Control messages are possible: It is possible to continue driving. High-voltage system. You can continue driving. Drivetrain. Restart not possible. Drivetrain fault. Call Roadside Assistance. Drivetrain failure. Information: Total error of vehicle. The following fault memory entries are stored in the CCU: D796D9 - Message (- 0x91) not up-to-date, receiver CCU, transmitter EME D796DC - No message (- 0x91), receiver CCU, transmitter EME D796D8 - No message (- 0x91), receiver CCU, transmitter EME Other fault codes below may be stored in the EGS BA09B8 Inverter, Voltage Sensor, 5V HV AUX: Out of range or open connection detected BA0A45 ECU internal: Internal error of the synchronous serial data bus. Additional fault memory entries are possible. Similar fault memory entries indicating a missing EMEmessage (Traction E-Machine Electronic) can also be stored in other control units.

NHTSA · نشرة المصنع11030054سنوات الطراز 2026معروض باللغة الأصلية (الإنجليزية) · الترجمة قيد الانتظارعرض التفاصيل →
إم 5 (G90/G99) · 2024–
نشرةمتوسطالكهرباءNA

نشرة

After performing a cabin air filter replacement maintenance service task, or after a similar repair thatrequired the removal and installation of the filters housing cover; the following air flap and/or air temperaturesensor faults are stored in the BCP: 80114D - Stepper motor: Unexpected error in Driving Cycle 801168 - Temperature sensor ventilation left or ventilation: short to ground 80116A - Temperature sensor ventilation right: short to ground 80116B - Temperature sensor ventilation right: short to plus or open circuit 80116C - Temperature sensor footwell left or footwell: short to ground 80116D - Temperature sensor footwell left or footwell: short to plus or open circuit 80116E - Temperature sensor footwell right: short to ground 80116F - Temperature sensor footwell right: short to plus or open circuit 80435B - Stepper motors: short-circuit by mass

NHTSA · نشرة المصنع11021112سنوات الطراز 2025معروض باللغة الأصلية (الإنجليزية) · الترجمة قيد الانتظارعرض التفاصيل →
إم 5 (G90/G99) · 2024–
نشرةمتوسطالكهرباءNA

نشرة

BMW AG has issued a Delivery Stop(effective July 11, 2025) on certain Model Year2025 - 2026 BMW vehicles that were produced between March 24, 2025, and April16, 2025. The heat insulator (highlighted in orange) for the bulkhead was not installed. Thermal overload of the components located in the area cannot be ruled out.

NHTSA · نشرة المصنع11021110سنوات الطراز 2025معروض باللغة الأصلية (الإنجليزية) · الترجمة قيد الانتظارعرض التفاصيل →
إم 5 (F10) · 2011–2016
نشرةمتوسطالكهرباءNA

نشرة

Coolant is leaking from under the car which is equipped with the N63 engine. A low coolant warning might also be displayed (CC Message ID166).

NHTSA · نشرة المصنع10218366معروض باللغة الأصلية (الإنجليزية) · الترجمة قيد الانتظارعرض التفاصيل →
إم 5 (F10) · 2011–2016
نشرةمتوسطالكهرباءNA

نشرة

Butt connector for repairing a plug connection. The ?top up coolant? message is displayed in the central display (CC message ID 166). When checking the cooling system there are no leaks found and the expansion tank is filled to the proper level.

NHTSA · نشرة المصنع10193494سنوات الطراز 2013معروض باللغة الأصلية (الإنجليزية) · الترجمة قيد الانتظارعرض التفاصيل →
إم 5 (F90) · 2017–2023
نشرةمتوسطالكهرباءNA

نشرة

Low Washer Fluid Warning Light is illuminated when the Washer Fluid Tank is Full : The low washer fluid warning is illuminated even though the washer fluid reservoir is full. There are no faults stored in the system for the washer fluid level switch. A non-approved washer fluid was used that is silicone-based. Silicone-based fluids are not compatible with the contactless capacitive level sensor. Fluids that contain a silicone additive are normally colored other than blue.

NHTSA · نشرة المصنع10169468سنوات الطراز 2017–2018معروض باللغة الأصلية (الإنجليزية) · الترجمة قيد الانتظارعرض التفاصيل →
إم 5 (F90) · 2017–2023
نشرةمتوسطالكهرباءNA

نشرة

ERRONEOUS FAULT 1F2505 IS STORED IN THE DME This Service Information bulletin replaces SI B12 30 18 dated November 2018. This fault does not cause any drivability complaints or engine warning lamps.

NHTSA · نشرة المصنع10163998سنوات الطراز 2017معروض باللغة الأصلية (الإنجليزية) · الترجمة قيد الانتظارعرض التفاصيل →
إم 5 (F10) · 2011–2016
نشرةمتوسطالكهرباءNA

نشرة

N55 Engine: Various Faults Stored in DME Related to VANOS and Camshaft Position. A rattling noise can be heard from the engine compartment; the engine has a loss of power; and the Service Engine Soon lamp is illuminated. One or more of the following faults may be stored. E70, E71, E82, E88, E90, E92 and E93: 2D5A - VANOS, intake: control fault, camshaft sticking 2D5B - VANOS, intake: control fault, position not reached 2D60 - VANOS, exhaust: control fault, camshaft sticking 2D61 - VANOS, exhaust: control fault, position not reached 2D9F - camshaft input sensor: signal implausible 2DA1 - Camshaft exhaust sensor: signal implausible 300C - Camshaft input sensor: signal high 300D - Camshaft input sensor: signal low 300E - Camshaft exhaust sensor: signal high 300F - Camshaft exhaust sensor: signal low F07, F10, F12, F13 and F25: 130104 - VANOS, intake: control fault, camshaft sticking 130108 - VANOS, intake: control fault, position not reached 130304 - VANOS, exhaust: control fault, camshaft sticking 130308 - VANOS, exhaust: control fault, position not reached 130E11 - Camshaft input sensor: signal implausible 130F11 - Camshaft exhaust sensor: signal implausible 164020 - Camshaft input sensor: signal high 164021 - Camshaft input sensor: signal low 164030 - Camshaft exhaust sensor: signal high 164031 - Camshaft exhaust sensor: signal low CAUSE One or both (intake and/or exhaust) of the VANOS gear assemblies have failed; the attaching bolts may have also loosened and/or broken.

NHTSA · نشرة المصنع10162395سنوات الطراز 2013معروض باللغة الأصلية (الإنجليزية) · الترجمة قيد الانتظارعرض التفاصيل →
إم 5 (F90) · 2017–2023
نشرةمتوسطالكهرباءNA

نشرة

VEHICLE DOES NOT START BATTERY TOTALLY DISCHARGED This Service Information bulletin replaces SI B61 04 19 dated March 2019.

NHTSA · نشرة المصنع10160348سنوات الطراز 2017–2018معروض باللغة الأصلية (الإنجليزية) · الترجمة قيد الانتظارعرض التفاصيل →
إم 5 (F90) · 2017–2023
نشرةمتوسطالكهرباءNA

نشرة

The Low Washer Fluid Warning Light is illuminated when the Washer Fluid Tank is Full This Service Information bulletin supersedes SI B61 23 15 dated April 2016.

NHTSA · نشرة المصنع10160350سنوات الطراز 2017–2018معروض باللغة الأصلية (الإنجليزية) · الترجمة قيد الانتظارعرض التفاصيل →
إم 5 (F90) · 2017–2023
نشرةمتوسطالكهرباءNA

نشرة

VEHICLE DOES NOT START BATTERY TOTALLY DISCHARGED This Service Information bulletin replaces SI B61 04 19 dated March 2019.

NHTSA · نشرة المصنع10160265سنوات الطراز 2017–2018معروض باللغة الأصلية (الإنجليزية) · الترجمة قيد الانتظارعرض التفاصيل →
إم 5 (F90) · 2017–2023
نشرةمتوسطالكهرباءNA

نشرة

The Low Washer Fluid Warning Light is illuminated when the Washer Fluid Tank is Full This Service Information bulletin supersedes SI B61 23 15 dated April 2016.

NHTSA · نشرة المصنع10160267سنوات الطراز 2017–2018معروض باللغة الأصلية (الإنجليزية) · الترجمة قيد الانتظارعرض التفاصيل →
إم 5 (F90) · 2017–2023
نشرةمتوسطالكهرباءNA

نشرة

THE VEHICLE DOES NOT START BATTERY TOTALLY DISCHARGED. The customer's vehicle does not start due to a totally discharged battery.

NHTSA · نشرة المصنع10159134سنوات الطراز 2017–2018معروض باللغة الأصلية (الإنجليزية) · الترجمة قيد الانتظارعرض التفاصيل →
إم 5 (F10) · 2011–2016
نشرةمتوسطالكهرباءNA

نشرة

"The customer complains that the ""low engine oil"" message is displayed too frequently. CAUSE The cause is related to, but not limited to, one or more of the following components and systems shown below: * Turbocharger * Crankcase ventilation * Engine gasket leaks * Internal engine tolerances and sealing * Improper filling or topping up Use the troubleshooting procedure below to help identify the cause."

NHTSA · نشرة المصنع10152343سنوات الطراز 2013معروض باللغة الأصلية (الإنجليزية) · الترجمة قيد الانتظارعرض التفاصيل →
إم 5 (F10) · 2011–2016
نشرةمتوسطالكهرباءNA

نشرة

BMW Parts Bulletin TEC1T RDC Module Return BMW NA has requested the inspection of the following part numbers: 36 10 6 856 227 and 36 10 6 798 872 Stock should not be sold or installed on any vehicle. Please return the part(s) to your facing Regional Distribution Center (RDC). Submit for return using a YR26 damage claim with order reason BM2. A valid BMW delivery and delivery item number must be entered, and TEC1T must appear in the text of your TEC claim. TEC1T is valid from May 30, 2013, through June 13, 2013.The deadline for filing a claim under TEC1T is June 13, 2013. All parts must be returned to your facing RDC no later than June 27, 2013. Part number 36 10 6 856 227: All parts with an index of 02 and older must be returned. All parts with an index of 03 are correct. Part number 36 10 6 798 872: All parts with an index of 03 and older must be returned. All parts with an index of 04 are correct. The Index is the two digit code under the bar code located on the box label. The Index can also be found on the part itself just after the part number. Please re-order the same part number as needed. (c) 2013, BMW of North America, LLC. The contents of this document are confidential and should not be shared with third parties for distribution.

NHTSA · نشرة المصنع10150084معروض باللغة الأصلية (الإنجليزية) · الترجمة قيد الانتظارعرض التفاصيل →
إم 5 (F10) · 2011–2016
نشرةمتوسطالكهرباءNA

نشرة

CLOSED-CIRCUIT CURRENT MONITORING. Increased closed-circuit currents may occur permanently or intermittently and cause the battery to discharge prematurely. The increase in closed-circuit current may be caused by a faulty control module or by the installation of a non-approved accessory. In a situation where a vehicle has broken down due to a discharged battery, for diagnostic purposes it is important not to disconnect the battery. This is because a control module will be reset if the battery is disconnected. Following a reset, the faulty control module may start functioning correctly again, making accurate diagnosis impossible. To correctly measure closed-circuit current, the 50-amp or 100-amp clip-on probe can be used in conjunction with the IMIB (Integrated Measurement Interface Box) to properly diagnose closed-circuit current problems over an extended period of time.

NHTSA · نشرة المصنع10149555معروض باللغة الأصلية (الإنجليزية) · الترجمة قيد الانتظارعرض التفاصيل →
إم 5 (F10) · 2011–2016
نشرةمتوسطالكهرباءNA

نشرة

2013 MINI JCW Paddle Shifter Retrofit. SZL to EGS harness installation. For necessary preliminary tasks, refer to ISTA and perform the following steps listed in this document.

NHTSA · نشرة المصنع10149498معروض باللغة الأصلية (الإنجليزية) · الترجمة قيد الانتظارعرض التفاصيل →
إم 5 (F10) · 2011–2016
نشرةمتوسطالكهرباءNA

نشرة

N63: Proper Ignition Harness Installation and Ground Connections. INFORMATION https://www.bmwtis.net/tiscode/cgi-bin/bulletin.aspx?sie_path=/tsb/bulletins/htm_store/16511.1.B12241... 10/14/2014 Page 2 of 2 Any consecutive damage to the BSD interface components (DME, alternator voltage regulator, QLT sensor) caused by incorrect reinstallation of the ignition harness is not covered under the BMW New Vehicle /SAV Limited Warranty.

NHTSA · نشرة المصنع10148021معروض باللغة الأصلية (الإنجليزية) · الترجمة قيد الانتظارعرض التفاصيل →
إم 5 (F10) · 2011–2016
نشرةمتوسطالكهرباءNA

نشرة

## متطلبات صيانة البطارية: العناية بالبطارية تُعدّ الصيانة السليمة للبطارية أمراً حيوياً عندما تكون مركبات BMW ضمن مخزون مركزك. إن السماح لجهد بطارية المركبة بالانخفاض دون 12.0 فولت (12.0V) يقلل بشكل دائم من العمر الافتراضي للبطارية، وقد يؤدي إلى تعطلها المبكر. أما بالنسبة للمركبات المزودة ببطارية الجهد العالي (المركبات الهجينة/الكهربائية)، فإن الإخفاق في صيانة هذه البطارية بشكل صحيح قد يؤدي إلى تفريغ كبير لبطارية الجهد العالي (HV)، ما يستلزم استبدالها. نوفر نظام صيانة مرناً للبطاريات يمكن لكل مركز BMW استخدامه بما يتوافق مع احتياجاته الخاصة. تشرح هذه النشرة تقويم شحن البطارية (انظر المرفق)، وأنظمة الشحن، وإجراء أداة مبسط وفحص جهد البطارية أدناه.

NHTSA · نشرة المصنع10148035ترجمة آلية · اللغة الأصلية: الإنجليزيةعرض التفاصيل →
إم 5 (F10) · 2011–2016
نشرةمتوسطالكهرباءNA

نشرة

BMW Parts Bulletin TEC9V Fuel Tank / Level Sensor Returns BMW AG has requested an inspection of the following part numbers: 16 11 7 268 031, 16 11 7 268 032 and 16 11 7 297 340 Stock should not be sold or installed on any vehicle. 16 11 7 268 031 and 16 11 7 268 032 All fuel tanks produced before 05/30/2014 needs to be returned. All parts with later dates of production are ok and can be used. 16 11 7 297 340 All level sensors produced in Poland before 05/19/2014 (date is shown as day 139 of year 14 on the part) need to be returned. Those produced after this date are ok and can be used. All level sensors produced in Brazil currently in dealer inventory need to be returned. Please return all part(s) to your facing Regional Distribution Center (RDC). Submit for return using a YR26 damage claim with order reason BM2. A valid BMW delivery and delivery item number must be entered, and TEC9V must appear in the text of your TEC claim. TEC9V is valid from September 24, 2014, through October 08, 2014. The deadline for filing a claim under TEC9V is October 08, 2014. All parts must be returned to your facing RDC no later than October 22, 2014. Please re-order the same part numbers as needed. (c) 2014, BMW of North America, LLC. The contents of this document are confidential and should not be shared with third parties for distribution. Page 2 / 2 Made in Poland Made in Brazil Need to be returned (c) 2014, BMW of North America, LLC. The contents of this document are confidential and should not be shared with third parties for distribution.

NHTSA · نشرة المصنع10148044معروض باللغة الأصلية (الإنجليزية) · الترجمة قيد الانتظارعرض التفاصيل →
إم 5 (F10) · 2011–2016
نشرةمتوسطالكهرباءNA

نشرة

BMW Parts Bulletin TEC3W Leak Diagnosis Module Return BMW AG has requested a return of the following part numbers: 16 13 7 315 813 and 16 13 7 274 147 Stock should not be sold or installed on any vehicle. Leak Diagnosis Module part number 16 13 7 315 813 must be returned. Please reorder new part number 16 13 7 333 302 as needed. Pressure Switch, Leak Diagnosis Module part number 16 13 7 274 147 must also be returned. Please reorder new part number 16 13 7 333 301 as needed. Please return all part(s) to your facing Regional Distribution Center (RDC). Submit for return using a YR26 damage claim with order reason BM2. A valid BMW delivery and delivery item number must be entered, and TEC3W must appear in the text of your TEC claim. TEC3W is valid from September 04, 2014, through September 18, 2014. The deadline for filing a claim under TEC3W is September 18, 2014. All parts must be returned to your facing RDC no later than October 02, 2014.

NHTSA · نشرة المصنع10148045معروض باللغة الأصلية (الإنجليزية) · الترجمة قيد الانتظارعرض التفاصيل →
إم 5 (F10) · 2011–2016
نشرةمتوسطالكهرباءNA

نشرة

BMW Parts Bulletin TEC1U RDC Module Return BMW AG has requested an inspection of the following part numbers: 36 10 6 798 872 and 36 10 6 856 227 Stock should not be sold or installed on any vehicle. All parts with a date of and from 26/07/13 (July 26, 2013) are good. All parts with a date prior to 26/7/13 (July 26, 2013) must be returned to your facing Regional Distribution Center (RDC). Submit for return using a YR26 damage claim with order reason BM2. A valid BMW delivery and delivery item number must be entered, and TEC1U must appear in the text of your TEC claim. TEC1U is valid from March 5, 2014, through March 19, 2014.The deadline for filing a claim under TEC1U is March 19, 2014. All parts must be returned to your facing RDC no later than April 2, 2014. Please re-order the same part number as needed. (c) 2014, BMW of North America, LLC. The contents of this document are confidential and should not be shared with third parties for distribution.

NHTSA · نشرة المصنع10148013معروض باللغة الأصلية (الإنجليزية) · الترجمة قيد الانتظارعرض التفاصيل →
إم 5 (F10) · 2011–2016
نشرةمتوسطالكهرباءNA

نشرة

TEC9T Return, Battery AGM. BMW AG has requested an inspection and return of affected batteries with the following part number: 61 21 8 520 153: Battery AGM Please inspect your stock of this battery. Batteries with finish code label E3, F3, G3, H3, I3, J3 and K3 should not be sold or installed on any motorcycle and must be held for scrapping by your ACM or FSE.

NHTSA · نشرة المصنع10147993معروض باللغة الأصلية (الإنجليزية) · الترجمة قيد الانتظارعرض التفاصيل →
إم 5 (F10) · 2011–2016
نشرةمتوسطالكهرباءNA

نشرة

Closed-circuit Current Measurement. Increased closed-circuit currents may occur permanently or intermittently, and may cause the battery to discharge prematurely. The increase in closed-circuit current may be caused by a faulty control unit, or by the installation of a non-approved accessory. In a situation where a vehicle has broken down due to a discharged battery, for diagnostic purposes it is important not to disconnect the battery. This is because a control unit will be reset if the battery is disconnected. Following a reset, the faulty control unit may start functioning correctly again, making accurate diagnosis impossible. To correctly measure closed-circuit current, the 50-amp clip-on probe (previously used with the IMIB) or the 100-amp clip-on probe can now be used in conjunction with the IMIB (Integrated Measurement Interface Box) to properly diagnose closed-circuit current problems over an extended period of time. Connect the amp clip-on probe directly to the IMIB Measurement input 3 (green socket).

NHTSA · نشرة المصنع10147940معروض باللغة الأصلية (الإنجليزية) · الترجمة قيد الانتظارعرض التفاصيل →
الأقدم →

المصادر: NHTSA (الولايات المتحدة، ملك عام)، وزارة النقل الكندية (رخصة الحكومة المفتوحة – كندا)، DVSA (المملكة المتحدة، رخصة الحكومة المفتوحة 3.0)، RappelConso وSafety Gate الأوروبي (فرنسا، الرخصة المفتوحة 2.0)، ووزارة MLIT اليابانية (رخصة البيانات العامة 1.0)، ووزارة MOLIT الكورية (car.go.kr).