Free to read · free account to contributeSuccessor to Anticars (2000)

Kia EV3

2024– · 1 generations · 0 documented defects · 2 markets
Generations
All generationsEV32024–31
Model year
MarketAllKRUK
RecallModerateElectricalKR

Miscellaneous Devices / Other

Instrument cluster recall due to possible excessive protection logic: if excessive noise occurs in a specific device within the instrument cluster, the internal temperature sensor may misdetect it as high temperature, and overall instrument cluster performance may be limited. In such cases, the instrument cluster may slow down or shut off (this may not conform to Safety Standard Article 110 of the Rules on the Performance and Standards of Motor Vehicles and Motor Vehicle Parts). <Production dates by target vehicle> EV3 (SV1): 2025.07.02~2025.10.13 EV4 (CT1): 2025.07.09~2025.09.22 EV6 (CV1 PE): 2025.07.01~2025.12.17 EV9 (MV1): 2025.06.24~2025.11.01 K5 (DL3 PE): 2025.06.30~2025.10.29 K5 HEV (DL3 HEV PE): 2025.06.30~2025.10.29 K8 (GL3 PE): 2025.07.01~2025.10.27 K8 HEV (GL3 HEV PE): 2025.07.01~2025.10.28 Sportage (NQ5 PE): 2025.06.25~2025.10.23 Sportage Hybrid (NQ5 HEV PE): 2025.06.25~2025.10.23 Sorento (MQ4 PE): 2025.07.09~2025.10.18 Sorento Hybrid (MQ4 HEV PE): 2025.06.30~2025.10.20 Carnival (KA4 PE): 2025.06.25~2025.10.22 Carnival Hybrid (KA4 HEV PE): 2025.06.24~2025.10.28 Tasman (TK1): 2025.07.02~2025.10.15 PV5 (SW1): 2025.07.27~2025.12.03

MOLIT · South KoreaFeb 11, 20266056Model years 2025Auto-translated · original: KoreanView details →
RecallModerateInteriorKR

실내안전장치 기타

A필러(LH) 트림 테더클립 미체결로 커튼 에어백 전개 시 A필러(LH) 트림이 이탈되어 고객 상해 발생 가능성이 확인됨에 따른 리콜 <대상차량별 생산일자> EV3: 2025.07.01~205.07.09 EV4: 2025.07.01~2025.07.08

MOLIT · South KoreaSep 24, 20255850Model years 2025Shown in the original Korean · translation pendingView details →
RecallMinorElectricalUK

Kia Cluster Malfunction Recall

The instrument cluster screen may respond slowly immediately after starting the vehicle. During this condition activating the turn signal can cause the cluster to reset or the Blind View Monitor (BVM) within the cluster to turn green. The malfunction is caused by PMIC noise induced falsely high temperature sensor readings which trigger the chip protection logic above a certain threshold and lead to performance limitation up to reboot or black screen.

DVSA · United KingdomApr 24, 2026R/2026/139Model years 2025View details →