Lectura libre · cuenta gratuita para colaborarSucesor de Anticars (2000)
Iniciar sesiónCrear cuenta
NANHTSA · boletín del fabricante10162461

Boletines técnicos

Mostrado en inglés original · traducción pendiente

Air Conditioning System Leak Testing. The customer complains of poor or no air conditioning cooling. After further diagnosis, the system is found to be low or empty of a refrigerant charge, but when using an electronic leak detector, no leak can be found. CAUSE: In most cases, an electronic leak detector is not sufficient for identifying small leaks in the system. Electronic leak detectors can give false alarms and can lead to an improper diagnosis of small leaks. A leak cannot be located exactly if accessibility is impaired (in the case of the expansion valve, evaporator or condenser).

Afecta a: Mini Hatch II (Años modelo 2009)

Aviso oficial ↗

Fuentes: NHTSA (Estados Unidos, dominio público), Transport Canada (Licencia de Gobierno Abierto – Canadá), DVSA (Reino Unido, Open Government Licence v3.0), RappelConso y Safety Gate de la UE (Francia, Licence Ouverte 2.0).