Lecture libre · compte gratuit pour contribuerSuccesseur d’Anticars (2000)
Se connecterCréer un compte
NANHTSA · bulletin constructeur11021112

Bulletins techniques

Affiché en anglais d’origine · traduction en attente

After performing a cabin air filter replacement maintenance service task, or after a similar repair thatrequired the removal and installation of the filters housing cover; the following air flap and/or air temperaturesensor faults are stored in the BCP: 80114D - Stepper motor: Unexpected error in Driving Cycle 801168 - Temperature sensor ventilation left or ventilation: short to ground 80116A - Temperature sensor ventilation right: short to ground 80116B - Temperature sensor ventilation right: short to plus or open circuit 80116C - Temperature sensor footwell left or footwell: short to ground 80116D - Temperature sensor footwell left or footwell: short to plus or open circuit 80116E - Temperature sensor footwell right: short to ground 80116F - Temperature sensor footwell right: short to plus or open circuit 80435B - Stepper motors: short-circuit by mass

Concerne: BMW 5 Series (G60) (Années modèle 2025) · BMW 7 Series (G70) (Années modèle 2025) · BMW M5 (G90/G99) (Années modèle 2025)

Avis officiel ↗

Sources : NHTSA (États-Unis, domaine public), Transports Canada (Licence du gouvernement ouvert – Canada), DVSA (Royaume-Uni, Open Government Licence v3.0), RappelConso et Safety Gate de l'UE (France, Licence Ouverte 2.0), MLIT (Japon, licence de données publiques 1.0) et MOLIT (Corée du Sud, car.go.kr).