Lecture libre · compte gratuit pour contribuerSuccesseur d’Anticars (2000)
Se connecterCréer un compte
NANHTSA · bulletin constructeur11030059

Bulletins techniques

Affiché en anglais d’origine · traduction en attente

The customer states there is a Drivetrain Malfunction message displayed in the instrument cluster. In addition, the following fault memory entries are saved in the CCU (Combined Charging Unit) 0317F2 - High-voltage system, insulation fault detected: when switch contactors are closed. 0317F1 - High-voltage system, insulation resistance below warning threshold: when switch contactors are closed. The fault memory entries (isolation faults) can occur both individually and in combination and must be traced back to the eDrive motor based on the ISTA test procedure. If ISTA test procedure lists possible cause of fault as; A metal chip is found behind the brush module (between the brush module and the end shield of the electrical machine). Repair required. Refer to service solution no. 20000794435083 in Aftersales Information Research (AIR). Follow information in the Procedure section below.

Concerne: BMW i5 (Années modèle 2024)

Avis officiel ↗

Sources : NHTSA (États-Unis, domaine public), Transports Canada (Licence du gouvernement ouvert – Canada), DVSA (Royaume-Uni, Open Government Licence v3.0), RappelConso et Safety Gate de l'UE (France, Licence Ouverte 2.0), MLIT (Japon, licence de données publiques 1.0) et MOLIT (Corée du Sud, car.go.kr).