UKDVSA · Royaume-UniR/2018/23717 sept. 2018

Control logic which monitors the charging control program fails to divert electrical power away from capacitor in the event of a fault

Affiché en anglais d’origine · traduction en attente

On the subject vehicles the control logic which monitors the charging control program fails to divert the electrical power away from the capacitor when a fault is detected within the capacitor circuit. This can cause a short circuit inside the DCDC converter and could cause the engine to stall or overheating of the DCDC converter itself which could cause a fire. The fault is accompanied by the �i-ELOOP� warning light being illuminated on the instrument cluster along with the �i-Stop� warning light flashing The engine may in some circumstances stall and fail to restart. In extreme cases the DCDC converter could overheat and cause a fire

Solution: Reprogram the PCM with the correct control logic. If error code �U3000: 49-DCDC� is stored � the DCDC Converter must also be replaced.

Concerne: Mazda CX-3 (Années modèle 2015–2017) · Mazda MX-5 (NC) (Années modèle 2015) · Mazda MX-5 (ND) (Années modèle 2016–2017)

Avis officiel ↗

Sources : NHTSA (États-Unis, domaine public), Transports Canada (Licence du gouvernement ouvert – Canada), DVSA (Royaume-Uni, Open Government Licence v3.0), RappelConso et Safety Gate de l'UE (France, Licence Ouverte 2.0), MLIT (Japon, licence de données publiques 1.0) et MOLIT (Corée du Sud, car.go.kr).