A faulty electric auxiliary heater may have been installed in the certain vehicles. This could result in thefailure of the electric auxiliary heater, utilized for the vehicle interior.

NHTSA · bollettino del costruttore11026956Anni modello 2024Mostrato in inglese originale · traduzione in attesaVedi dettagli →
BollettinoModeratoElettronicaNA

Bollettino

A faulty electric auxiliary heater may have been installed in the certain vehicles. This could result in the failure of the electric auxiliary heater.

NHTSA · bollettino del costruttore11019570Anni modello 2024Mostrato in inglese originale · traduzione in attesaVedi dettagli →
BollettinoModeratoElettronicaNA

Bollettino

The coolant hose which runs from the combined charging unit (CCU) to the front electric motors housingmay develop a leak at the motor end of the hose.

NHTSA · bollettino del costruttore11017503Anni modello 2025Mostrato in inglese originale · traduzione in attesaVedi dettagli →
BollettinoModeratoElettronicaNA

Bollettino

A manufacturing defect in high-voltage cells of the high-voltage battery can result in electrolyte leakage which might result in a conductive connection with surrounding components. Depending on the contact resistance, a yellow or red Check Control message will then be displayed; it is permitted for you to continue driving, but this will result in a charging interruption during charging.

NHTSA · bollettino del costruttore11008114Anni modello 2024Mostrato in inglese originale · traduzione in attesaVedi dettagli →
BollettinoLieveElettronicaNA

Bollettino

Charging sessions cannot be started or they are interrupted while using a Level 2 AC high-power chargingstation, or with a Level 3 DC charging station. Charging may start normally but can interrupt after some time. Level 2 (240 V) Flex Charger and Wall boxmay also be affected. The red or white LED is displayed on the high-voltage charging socket; however, no associated fault codesare stored.

NHTSA · bollettino del costruttore11034463Anni modello 2025Mostrato in inglese originale · traduzione in attesaVedi dettagli →
BollettinoLieveElettronicaNA

Bollettino

Charging sessions cannot be started or they are interrupted while using a Level 2 AC high-power charging station, or with a Level 3 DC charging station. Charging may start normally but can interrupt after some time. Level 2 (240 V) Flex Charger and Wall box may also be affected. The red or white LED is displayed on the high-voltage charging socket; however, no associated fault codes are stored.

NHTSA · bollettino del costruttore11031568Anni modello 2024Mostrato in inglese originale · traduzione in attesaVedi dettagli →
BollettinoLieveElettronicaNA

Bollettino

The customer states there is a Drivetrain Malfunction message displayed in the instrument cluster. In addition, the following fault memory entries are saved in the CCU (Combined Charging Unit) 0317F2 - High-voltage system, insulation fault detected: when switch contactors are closed. 0317F1 - High-voltage system, insulation resistance below warning threshold: when switch contactors are closed. The fault memory entries (isolation faults) can occur both individually and in combination and must be traced back to the eDrive motor based on the ISTA test procedure. If ISTA test procedure lists possible cause of fault as; A metal chip is found behind the brush module (between the brush module and the end shield of the electrical machine). Repair required. Refer to service solution no. 20000794435083 in Aftersales Information Research (AIR). Follow information in the Procedure section below.

NHTSA · bollettino del costruttore11030059Anni modello 2024Mostrato in inglese originale · traduzione in attesaVedi dettagli →
BollettinoLieveElettronicaNA

Bollettino

High Voltage Connection Return

NHTSA · bollettino del costruttore11029015Anni modello 2024Mostrato in inglese originale · traduzione in attesaVedi dettagli →
BollettinoLieveElettronicaNA

Bollettino

RSU availability. It is possible the State of Health (SoH) of the high-voltage (HV) battery is displayed incorrectly to the customer. The value is continuously displayed as 100% regardless of the actual ageing of the HV battery.

NHTSA · bollettino del costruttore11024714Anni modello 2025Mostrato in inglese originale · traduzione in attesaVedi dettagli →
BollettinoLieveElettronicaNA

Bollettino

Delivery Stop Electric Auxiliary Heater

NHTSA · bollettino del costruttore11018736Anni modello 2024Mostrato in inglese originale · traduzione in attesaVedi dettagli →
BollettinoLieveElettronicaNA

Bollettino

The operating time value was written too high in the Storage Management Electronics (SME) during thehigh-voltage battery End Of Line (EOL) test. The excessive operating hours input results in a significant limitation in the charging capacity when vehicleis be charged with DC.

NHTSA · bollettino del costruttore11018729Anni modello 2025Mostrato in inglese originale · traduzione in attesaVedi dettagli →
BollettinoLieveElettronicaNA

Bollettino

The customer states there is a Drivetrain Malfunction message displayed in the instrument cluster. In addition, the following fault memory entries are saved in the CCU (Combined Charging Unit) 0317F2 - High-voltage system, insulation fault detected: when switch contactors are closed. 0317F1 - High-voltage system, insulation resistance below warning threshold: when switch contactors are closed. The fault memory entries (isolation faults) can occur both individually and in combination and must be traced back to the eDrive motor based on the ISTA test procedure. If ISTA test procedure lists possible cause of fault as; A metal chip is found behind the brush module (between the brush module and the end shield of the electrical machine). Repair required. Refer to service solution no. 20000794435083 in Aftersales Information Research (AIR). Follow information in the Procedure section below.

NHTSA · bollettino del costruttore11012080Anni modello 2024Mostrato in inglese originale · traduzione in attesaVedi dettagli →
BollettinoLieveElettronicaNA

Bollettino

Replace Cell Modules

NHTSA · bollettino del costruttore11006742Anni modello 2024Mostrato in inglese originale · traduzione in attesaVedi dettagli →
BollettinoLieveElettronicaNA

Bollettino

This Informational Bulletin is intended as a guided work through process to address BEV/PHEV charging issues. The step-by-step guide will help walk you through the correct basic steps that should be followed when addressing and diagnosing battery electric vehicles (BEV) and plug in hybrid vehicles (PHEV) charging issues.

NHTSA · bollettino del costruttore10252039Anni modello 2024Mostrato in inglese originale · traduzione in attesaVedi dettagli →
BollettinoLieveElettronicaNA

Bollettino

The customer states there is a Drivetrain Malfunction message displayed in the instrument cluster. In addition, the following fault memory entries are saved in the CCU (Combined Charging Unit) 0317F2 - High-voltage system, insulation fault detected: when switch contactors are closed. 0317F1 - High-voltage system, insulation resistance below warning threshold: when switch contactors are closed. The fault memory entries (isolation faults) can occur both individually and in combination and must be traced back to the eDrive motor based on the ISTA test procedure. If ISTA test procedure lists possible cause of fault as; A metal chip is found behind the brush module (between the brush module and the end shield of the electrical machine). Repair required. Refer to service solution no. 20000794435083 in Aftersales Information Research (AIR). Follow information in the Procedure section below.

NHTSA · bollettino del costruttore10250361Anni modello 2024Mostrato in inglese originale · traduzione in attesaVedi dettagli →
BollettinoLieveElettronicaNA

Bollettino

Gen 5 BEV/PHEV vehicles may set the Combined Charging Unit (CCU) in programming abort due to nocommunication to the HV charge socket electronics.

NHTSA · bollettino del costruttore10250365Anni modello 2024Mostrato in inglese originale · traduzione in attesaVedi dettagli →
BollettinoLieveElettronicaNA

Bollettino

The electrical system of BMW vehicles has been subject to an ongoing development process over the last few years. This has led to increased demands being placed on the battery. This document covers important information for the dealer on how to handle discharged battery complaints.

NHTSA · bollettino del costruttore10249027Anni modello 2024Mostrato in inglese originale · traduzione in attesaVedi dettagli →
BollettinoLieveElettronicaNA

Bollettino

Quality improvements and robustness measures are to be implemented on the affected vehicles via thissoftware update. The software update improves functions in the following areas of the head unit: 1. Bluetooth connection issues and Bluetooth malfunctions (disconnections) 2. Central display may remain black in rare cases 3. Personalization issues and the loss of normalization/sitting position 4. Missing Condition-Based Service (CBS) data

NHTSA · bollettino del costruttore10248088Anni modello 2024Mostrato in inglese originale · traduzione in attesaVedi dettagli →
BollettinoLieveElettronicaNA

Bollettino

The purpose of this Service Bulletin (SIB) is informational regarding DC (direct current) charging complaints on Gen 5 Battery Electric Vehicles (BEV). It serves as a supporting argument and is intended to help distinguish between a standard designed function or component operation from an actual system fault in a DC charging customer complaint (i.e., DC Not charging or DC charging too slow. Helpful Tips and Tricks have been included on each topic within the document that can be used as reference to aid in the diagnosis or in understanding the system. The situation involves several possible causes: 1. Limitation of charging power by the charging station or charging app configuration. 2. Decreasing charging power at a very high state of charge (SoC). 3. Too frequent DC charging attempts within a short period of time. 4. The high-voltage battery is not at the ideal temperature. 5. Ageing of the high-voltage battery.