NANHTSA · Stati Uniti97V0830005 mag 1997

Visibility:Rearview mirrors/devices

Mostrato in inglese originale · traduzione in attesa

A short circuit condition can occur in the remote power mirror control switch circuit board as a result of a separated part of the contact assembly bridging the switch positive battery pad and adjacent chassis ground pad.

Rischio: The current can overheat the printed circuit board and other plastic and elastomeric components of the switch assembly resulting in smoke or fire.

Rimedio: Dealers will install an in-line 10 amp fuse in the positive battery feed to the remote power mirror control switch assembly.

Riguarda: Ford Explorer I (Anni modello 1992–1994)