After performing a cabin air filter replacement maintenance service task, or after a similar repair thatrequired the removal and installation of the filters housing cover; the following air flap and/or air temperaturesensor faults are stored in the BCP: 80114D - Stepper motor: Unexpected error in Driving Cycle 801168 - Temperature sensor ventilation left or ventilation: short to ground 80116A - Temperature sensor ventilation right: short to ground 80116B - Temperature sensor ventilation right: short to plus or open circuit 80116C - Temperature sensor footwell left or footwell: short to ground 80116D - Temperature sensor footwell left or footwell: short to plus or open circuit 80116E - Temperature sensor footwell right: short to ground 80116F - Temperature sensor footwell right: short to plus or open circuit 80435B - Stepper motors: short-circuit by mass
NANHTSA · メーカー通報11021112
技術サービス通報
原文(英語)で表示中 · 翻訳待ち
対象: BMW 5 Series (G60) (モデルイヤー 2025) · BMW 7 Series (G70) (モデルイヤー 2025) · BMW M5 (G90/G99) (モデルイヤー 2025)