閲覧無料 · 投稿は無料アカウントでAnticars(2000年)の後継
ログインアカウント作成
UKDVSA · 英国R/2018/2372018年9月17日

Control logic which monitors the charging control program fails to divert electrical power away from capacitor in the event of a fault

原文(英語)で表示中 · 翻訳待ち

On the subject vehicles the control logic which monitors the charging control program fails to divert the electrical power away from the capacitor when a fault is detected within the capacitor circuit. This can cause a short circuit inside the DCDC converter and could cause the engine to stall or overheating of the DCDC converter itself which could cause a fire. The fault is accompanied by the �i-ELOOP� warning light being illuminated on the instrument cluster along with the �i-Stop� warning light flashing The engine may in some circumstances stall and fail to restart. In extreme cases the DCDC converter could overheat and cause a fire

対策: Reprogram the PCM with the correct control logic. If error code �U3000: 49-DCDC� is stored � the DCDC Converter must also be replaced.

対象: Mazda CX-3 (モデルイヤー 2015–2017) · Mazda MX-5 (NC) (モデルイヤー 2015) · Mazda MX-5 (ND) (モデルイヤー 2016–2017)

公式情報 ↗

出典:NHTSA(米国、パブリックドメイン)、カナダ運輸省(Open Government Licence – Canada)、DVSA(英国、Open Government Licence v3.0)、RappelConso および EU Safety Gate(フランス、Licence Ouverte 2.0)。