Service brake performance: excessively binding (frequent MOT failure)
3.7% of MOT tests of this car in Great Britain failed on this point (2,163 of 58,591 tests in 2025): 5.1 times as often as cars of the same age.
🔔 Crie uma conta gratuita para receber alertas por e-mail sobre Nissan Micra IV
Este dossiê reúne os defeitos conhecidos do Nissan Micra IV, escritos e documentados pela comunidade. A leitura é livre; uma conta gratuita permite contribuir. Um defeito recebe o selo quando colaboradores reconhecidos suficientes o validam.
3.7% of MOT tests of this car in Great Britain failed on this point (2,163 of 58,591 tests in 2025): 5.1 times as often as cars of the same age.
7.6% of periodic inspections of this car in Finland found a fault on this item serious enough to fail the car (236 faults in 3,122 inspections in 2025): 2.9 times as often as cars of the same age.
4.5% of MOT tests of this car in Great Britain failed on this point (2,657 of 58,591 tests in 2025): 2.7 times as often as cars of the same age.
O banco do condutor pode estar defeituoso, o que pode fazer com que os ancoragens do cinto de segurança não funcionem como previsto, criando um risco de lesão em caso de acidente.
On certain vehicles, a bad connection at the side airbag sensor connector could cause a momentary communication loss from the side airbag sensor to the Airbag Control Unit (ACU). This would put the system in a backup state, lowering the impact threshold required for a side airbag deployment. If a door is being closed with force while the system is in this backup state, this could cause an unintended curtain airbag, seat-mounted side airbag and seat belt pretensioner deployment in a non-warranted (non-impact) situation, which would increase the risk of injury to occupants. Correction: Dealers will install a jumper harness and replace the side airbag sensor with a new one.
The engine ignition coil may not be to the correct specification. The internal electrical components of the coil may short circuit resulting in an engine misfire. In the worst case this short circuit may cause a fuse inside the Power Distribution Module (IPDM) to fail stopping power to the ignition relay. In this condition the engine may stall and prevent the customer from being able to restart the engine.