通报
Issue: JLR have received a number of reports reference timing chain cover plugs. Customers may complain of engine oil leaks as these plugs have become loose or come adrift over time.
🔔 注册免费账户,接收 Jaguar E-Pace (所有代) 的邮件提醒
技术服务通报(TSB)是制造商就已知问题发给经销商的维修说明。它们不是安全召回,但常常能证实某个缺陷。
Issue: JLR have received a number of reports reference timing chain cover plugs. Customers may complain of engine oil leaks as these plugs have become loose or come adrift over time.
Issue: Injector Refit Kit (Service Part number: T2H33724) is shipped with BOSCH installation instruction sheet. Installation instructions are incorrect on the BOSCH installation sheet.
Issue: Diesel exhaust fluid (DEF) injector crystallization leading to incorrect and unnecessary replacement.
Issue: Diesel exhaust fluid (DEF) injector crystallization leading to incorrect and unnecessary replacement.
Issue: Diesel exhaust fluid (DEF) injector crystallization leading to incorrect and unnecessary replacement.
Issue: Diesel exhaust fluid (DEF) injector crystallization leading to incorrect and unnecessary replacement.
A customer may report the air conditioning system is not cooling intermittently.
Temperature settings revert from Fahrenheit to Celsius after an ignition cycle.
The variable coolant pump shroud is sticking causing electronic cooling fan to run at 100% duty cycle and/or illuminate the Check Engine MIL.
A 'clunk' noise may be evident from the front of the vehicle when the engine is switched OFF.
An issue has been identified on certain vehicles within the listed Affected Vehicle Range where if the vehicle has had Service Action H100, Climate Control Blowing Cold Air on One Side, performed prior to 20 March 2018 and the air conditioning compressor run-in routine not carried out will experience reduced Heating, Ventilation, and Air Conditioning (HVAC) system cooling performance as the compressor will not function as intended.
An issue has been identified on a limited number of Jaguar vehicles within the listed Affected Vehicle Range where if the vehicle has had Service Action H100, Climate Control Blowing Cold Air on One Side, performed prior to 20 March 2018 and the air conditioning compressor run-in routine not carried out will experience reduced Heating, Ventilation, and Air Conditioning (HVAC) system cooling performance as the compressor will not function as intended.
来源:NHTSA(美国,公有领域)、加拿大交通部(加拿大开放政府许可)、DVSA(英国,开放政府许可 v3.0)、RappelConso 与欧盟 Safety Gate(法国,开放许可 2.0)、日本国土交通省(公共数据许可1.0)、韩国国土交通部(car.go.kr)。