技術通報
After replacement of the Integrated Braking system (IB)/Power Brake the total distance covered might belower than when handed over to the workshop for the repair.
🔔 無料アカウントを作成して BMW i5 (すべての世代) のメール通知を受け取る
技術サービス通報(TSB)は、既知の不具合についてメーカーが販売店に送る修理指示です。安全リコールではありませんが、不具合の裏付けになることがよくあります。
After replacement of the Integrated Braking system (IB)/Power Brake the total distance covered might belower than when handed over to the workshop for the repair.
A faulty electric auxiliary heater may have been installed in the certain vehicles. This could result in thefailure of the electric auxiliary heater, utilized for the vehicle interior.
The parking brake actuator has not been wound correctly so that it cannot be applied or released. Check Control message Parking brake failed. When parking, secure the vehicle against rolling away. Mustbe checked by the Service Partner. The vehicle is still held by the unaffected side and the transmission lock.
A faulty electric auxiliary heater may have been installed in the certain vehicles. This could result in the failure of the electric auxiliary heater.
A loud click- type noise can be heard from the rear axle brakes when driving off forwards, and/or in reverse.
Parts of the steering shaft universal joint may have been joined together without having beengreased. As a result, there can be audible squeaking and cracking noises. In some cases, moresteering force is required.
The coolant hose which runs from the combined charging unit (CCU) to the front electric motors housingmay develop a leak at the motor end of the hose.
The parking brake actuator cannot be activated or deactivated due to a failed weld. Check Control message Parking brake failed. When parking, secure the vehicle against rolling away. Mustbe checked by the Service Partner. The vehicle is still held by the unaffected side and the transmission lock.
Parts of the steering shaft universal joint may have been joined together without having beengreased. As a result, there can be audible squeaking and cracking noises. In some cases, moresteering force is required.
Delivery stop: Steering shaft universal joint
After replacement of the Integrated Braking system (IB)/Power Brake the total distance covered might be lower than when handed over to the workshop for the repair.
Quality checks have determined that the coolant changeover valve may develop a coolant leak undervery low outside temperatures (significantly lower than 32 F (0 C)).
Improved diagnostic software for the brake system.
A manufacturing defect in high-voltage cells of the high-voltage battery can result in electrolyte leakage which might result in a conductive connection with surrounding components. Depending on the contact resistance, a yellow or red Check Control message will then be displayed; it is permitted for you to continue driving, but this will result in a charging interruption during charging.
Quality checks have determined that the coolant changeover valve may develop a coolant leak under very low outside temperatures (significantly lower than 32 F (0 C)).
Quality checks have determined that the coolant changeover valve may develop a coolant leak under very low outside temperatures (significantly lower than 32 F (0 C)).
The coolant changeover valve may develop a coolant leak when the outside temperatures go below 19F (-7C). The vehicles operating systems would also need to be at that same low temperature (example: being parked outside, overnight in low temperatures).
The coolant changeover valve may develop a coolant leak when the outside temperatures go below 19F (-7C). The vehicles operating systems would also need to be at that same low temperature (example: being parked outside, overnight in low temperatures).
Charging sessions cannot be started or they are interrupted while using a Level 2 AC high-power chargingstation, or with a Level 3 DC charging station. Charging may start normally but can interrupt after some time. Level 2 (240 V) Flex Charger and Wall boxmay also be affected. The red or white LED is displayed on the high-voltage charging socket; however, no associated fault codesare stored.
The vehicle will no longer move when put into gear. There may also be loud noise coming from the HEAT*(electric drivetrain)/Rear axles.
Charging sessions cannot be started or they are interrupted while using a Level 2 AC high-power charging station, or with a Level 3 DC charging station. Charging may start normally but can interrupt after some time. Level 2 (240 V) Flex Charger and Wall box may also be affected. The red or white LED is displayed on the high-voltage charging socket; however, no associated fault codes are stored.
The customer states there is a Drivetrain Malfunction message displayed in the instrument cluster. In addition, the following fault memory entries are saved in the CCU (Combined Charging Unit) 0317F2 - High-voltage system, insulation fault detected: when switch contactors are closed. 0317F1 - High-voltage system, insulation resistance below warning threshold: when switch contactors are closed. The fault memory entries (isolation faults) can occur both individually and in combination and must be traced back to the eDrive motor based on the ISTA test procedure. If ISTA test procedure lists possible cause of fault as; A metal chip is found behind the brush module (between the brush module and the end shield of the electrical machine). Repair required. Refer to service solution no. 20000794435083 in Aftersales Information Research (AIR). Follow information in the Procedure section below.
RSU availability. It is possible the State of Health (SoH) of the high-voltage (HV) battery is displayed incorrectly to the customer. The value is continuously displayed as 100% regardless of the actual ageing of the HV battery.
While attempting to fuel/charge the vehicle,the fuel/charge door will not open.
出典:NHTSA(米国、パブリックドメイン)、カナダ運輸省(Open Government Licence – Canada)、DVSA(英国、Open Government Licence v3.0)、RappelConso および EU Safety Gate(フランス、Licence Ouverte 2.0)、国土交通省(日本、公共データ利用規約1.0)、韓国国土交通部(car.go.kr)。