制动管路因腐蚀受损(常在APK检测中不合格)
在荷兰,该车的APK检测中有2.8%发现了此缺陷(过去12个月内5,594次检测中有157次):是同龄车辆的2.1倍。
🔔 注册免费账户,接收 Mazda 2 (所有代) 的邮件提醒
Mazda 2 所有代的全部信息:缺陷、召回、技术通报和讨论。选择某一代以缩小范围。
在荷兰,该车的APK检测中有2.8%发现了此缺陷(过去12个月内5,594次检测中有157次):是同龄车辆的2.1倍。
Bij 5,3% van de APK-keuringen van deze auto in Nederland werd dit gebrek vastgesteld (704 van 13.321 keuringen in de afgelopen 12 maanden): 84,4 keer zo vaak als bij auto's van dezelfde leeftijd.
12% of periodic inspections of this car in Finland found a fault on this item serious enough to fail the car (166 faults in 1,424 inspections in 2025): 3.0 times as often as cars of the same age.
NHTSA, the US road safety agency, opened an engineering analysis (EA21002) into this problem on 17 September 2021 for 2011–2013 models; it was still open.
NHTSA, the US road safety agency, opened an engineering analysis (EA21002) into this problem on 17 September 2021 for 2014 models; it was still open.
Het instrumentenpaneel kan door een softwarefout waarschuwingsmeldingen en de snelheid mogelijk onjuist weergeven.
On affected vehicles improper programming of the combination meter display may cause the display to become inoperable and remain blank. This prevents the speedometer from being visible.
L’écrou et la vis inférieure de fixation de l’amortisseur à la mâchoire de direction pourraient devenir lâches, conduisant à son détachement. cela pourrait entraîner une perte de contrôle sur le véhicule ou une altération de la stabilité au volant, ce qui pourrait augmenter le risque d’accident.
Some customers may complain about any of the following 1. Infotainment Center Display does not provide the Authorization Code (OTP) during the MyMazda App Connected Vehicle enrollment. 2. Remote function(s) inoperative.
Some vehicles may exhibit the check engine light ON with DTC P0300:00 (Random misfire detected) stored. This may be caused by a mis-detection of a misfire due to improper PCM control logic. To eliminate this concern, the PCM control logic has been modified.
Some customers may notice the charging lamp turns on while driving. Upon inspection, DTC P2502:00 PCM (Malfunction in voltage generated by generator) is stored in memory. This may be caused by resistance between the circuit board and ground. When high intensity electrical current passes through, the ground terminal position may not be sufficient enough. To eliminate this concern, the DC-DC converter control software has been modified. Additionally, the production procedure has been revised. The tightening torque for the ground terminal and circuit board was increased.
缺陷和讨论按代归档:请先在上方选择一代再发布。
来源:NHTSA(美国,公有领域)、加拿大交通部(加拿大开放政府许可)、DVSA(英国,开放政府许可 v3.0)、RappelConso 与欧盟 Safety Gate(法国,开放许可 2.0)。