Closed-circuit Current Measurement. Increased closed-circuit currents may occur permanently or intermittently, and may cause the battery to discharge prematurely. The increase in closed-circuit current may be caused by a faulty control unit, or by the installation of a non-approved accessory. In a situation where a vehicle has broken down due to a discharged battery, for diagnostic purposes it is important not to disconnect the battery. This is because a control unit will be reset if the battery is disconnected. Following a reset, the faulty control unit may start functioning correctly again, making accurate diagnosis impossible. To correctly measure closed-circuit current, the 50-amp clip-on probe (previously used with the IMIB) or the 100-amp clip-on probe can now be used in conjunction with the IMIB (Integrated Measurement Interface Box) to properly diagnose closed-circuit current problems over an extended period of time. Connect the amp clip-on probe directly to the IMIB Measurement input 3 (green socket).
NANHTSA · bulletin constructeur10147940
Bulletins techniques
Affiché en anglais d’origine · traduction en attente
Concerne: BMW 1 Series (F40) · BMW 2 Series II · BMW 3 Series (F30) · BMW 5 Series (E28) · BMW 6 Series (E63) · BMW 7 Series E65 · BMW 8 Series (G15) · BMW E24 · BMW Z4 M Coupé (E86) · BMW M Roadster Z4 M Coupé (E86) · BMW M1 · BMW F80 M3 · BMW M5 (F10) · BMW X5 · BMW Z3 · BMW Z4 (E89) · BMW Z8
Sources : NHTSA (États-Unis, domaine public), Transports Canada (Licence du gouvernement ouvert – Canada), DVSA (Royaume-Uni, Open Government Licence v3.0), RappelConso et Safety Gate de l'UE (France, Licence Ouverte 2.0), MLIT (Japon, licence de données publiques 1.0) et MOLIT (Corée du Sud, car.go.kr).